How it works
Virtual path
Guest vnet interfaces connect through a virtual switch (vsw) to other guests or a physical uplink. Inside Solaris, configure the interface with ipadm.
VLAN policy
Use port VLAN IDs and tagged VLANs deliberately; do not assume a virtual switch provides firewall segmentation.
Resilience
A guest with one virtual network connected to one service domain has a dependency on that service domain. Separate switches/services and IPMP may reduce single points of failure where supported.
Performance
Measure both guest and service domain, especially when the service domain handles substantial guest traffic.
Worked examples
Each example explains the question it answers, a reproducible starting point, what to look for, and operational precautions.
1. Inspect guest-to-switch mapping
Find which virtual switch serves each NIC.
ldm list-services
ldm list-bindings app01
dladm show-physInterpretation: Compare switch uplink to the intended physical network.
Operational note: Run commands in a test environment first; confirm device names, privileges and release-specific options.
2. Add an isolated VLAN-backed NIC
Illustrative guest interface with PVID 120.
ldm add-vnet pvid=120 appnet primary-vsw0 app01
ldm list-bindings app01Interpretation: The guest receives a virtual interface connected to the configured virtual network.
Operational note: Coordinate VLAN 120 on upstream switches; verify switch security and supported change behavior.
3. Configure Solaris guest IP
Configure a persistent static address on the guest.
dladm show-link
ipadm create-ip net0
ipadm create-addr -T static -a 192.0.2.20/24 net0/v4
ipadm show-addrInterpretation: Use the actual guest interface name; 192.0.2.0/24 is documentation-only addressing.
Operational note: Do not apply illustrative IP addresses to a live network.
4. Diagnose missing connectivity
Separate link, IP and route failures.
dladm show-link
ipadm show-if
ipadm show-addr
netstat -rn
ping 192.0.2.1Interpretation: If guest link is present but packets fail, inspect vnet/vsw binding and service-domain physical uplink.
Operational note: Run commands in a test environment first; confirm device names, privileges and release-specific options.
Before you finish
- Document physical uplinks and VLAN trunking.
- Check whether guest migration constraints include network topology.
Primary documentation
Read the relevant Oracle documentation for exact version-specific flags, supported platforms and limitations: Oracle primary reference ↗.
This field manual is independent, not affiliated with or endorsed by Oracle. Command examples should be adapted to your environment.